RomoCoat ZINC RICH EPOXY PRIMER-1265
RomaCoat Zinc Rich Epoxy Primer 1265 is a two‑pack metallic zinc‑rich epoxy primer designed as a high‑performance first coat for aggressive, highly corrosive environments.
What this primer is
- Two‑component epoxy primer with metallic zinc dust as the main pigment, giving strong cathodic (sacrificial) protection to steel.
- Used as the first coat in heavy‑duty anti‑corrosive systems for new construction and maintenance.

Where it is typically used
- Offshore and marine: jackets, platforms, jetties, splash zone steel and coastal structures.
- Petrochemical and oil & gas: process structures, pipe racks, tank externals, refineries and terminals.
- Bridges and infrastructure: highway and railway bridges, flyovers and exposed structural steel.
- Power plants and heavy industry: boiler structures, chimneys, conveyors, cranes and general plant steelwork.
Product Data Sheet
| Property | Details |
|---|---|
| Mixing Ratio | 4 : 1 by volume |
| Pot Life | 3 Hrs(30°C) |
| Application Methods | Airless Spray, Air Spray, Brush, Flow |
| Nozzle Orifice | 0.017” – 0.019” |
| Volume Solids | Approx. 45 ± 2 % |
| Finish | Matt |
| Colour | Grey |
| Recommended DFT / Coat | 60–100 microns |
| Theoretical Spreading Rate | 7.50-4.50 M2 /Ltr at above DFT |
| Surface Dry | 10-15 Min hour at 30°C |
| Through Dry | 1.50 – 2.00 hours |
| Fully Cured | 7 days at 30°C |
| Over coating Interval | Min: 12 hours to unlimited |
| Flash Point | Above 29°C |
| Thinner | Thinner for Zinc Rich Primer |
Key surface preparation & application notes
- Zinc‑rich coatings are porous; to reduce pinholes in the next coat, first apply a light mist coat, allow air to escape, then apply a full coat.
- If left exposed too long without topcoat, white rust (zinc corrosion products) will form and must be removed before overcoating.
- Steel must be dry, clean and abrasive‑blasted (typically Sa 2 for radiators, Sa 2½ for tanks); old coatings must be roughened sufficiently before applying this primer.
Health, safety and storage (short)
- Avoid inhalation of solvent vapour/paint mist and contact with skin/eyes; ensure forced ventilation in confined or stagnant areas and use PPE as per local regulations.
- Store in a cool, dry, well‑ventilated place; keep containers tightly closed and protected from direct sunlight and heat.